![]() Independent Acoustics and Noise Control Specialists |
![]() |
|
Robust Details | Acoustic Battens | Resilient Floor Battens | Acoustic Flooring | ||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() | ![]() |
Shallow and Deep - Acoustic Resilient Composite Floor Battens |
USES:
|
BENEFITS:
|
![]() |
The Isocheck shallow batten system is designed to reduce sound transmission through a concrete structural sub-floor and consists of a layer of 13mm LRC foam bonded to a softwood batten.
When installed as part of a complete party floor construction it enables a concrete floor to meet the sound transmission standards of ADE 2003 (amended 2004). Should the requirement be for a batten height other than that detailed on this page please contact us for further advise of suitability and availability. Product Data Overall Batten Size: 2400mm x 45mm x 45mm* Resilient Layer Thickness: 8mm Resilient Layer: X-link Isopol* alternative batten depths are available 54mm, 61mm and 70mm or custom to special order. |
|
Performance
Treated floor meets with the descriptive FFT3, typically within Robust Detail E-FC-2. Using deeper battens (min. 70mm would conform to FFT1 within E-FC-2 and E-FC-7.
Performance Treated floor meets with the descriptive FFT3, typically within Robust Detail E-FC-1. Using deeper battens (min. 70mm) would conform to FFT1 within E-FC-1 and E-FC-7.
|
|
SPECIFICATION:
The acoustic floor shall be: Isocheck Shallow Batten, by Custom Audio Designs Ltd, Unit 2, Amey Industrial Estate, Petersfield, Hampshire, GU32 3AN and installed in accordance with manufacturer's instructions / recommendations. | |
DOWNLOAD PDF
DOWNLOAD INSTALLATION DETAILS
|
|
EcoCheck Deep Batten system is designed to reduce sound transmission through timber floors within a timber frame structure.
EcoCheck Deep Batten consists of a batten bonded to 15mm LRAC. When installed as part of a complete party floor construction it enables a timber floor to meet the sound transmission stadards of ADE 2003 (amended 2004). Should the requirement be for a batten height higher than that detailed here please contact us for further technical advise and suitability. Product Data Overall Batten Size: 1800mm x 45mm x 75mm O/A Resilient Layer Thickness: Down to approx. 13mm under a normal domestic load. Resilient Layer: 15mm LRAC |
|
Performance
Treated floor meets with the descriptive FFT1, typically within Robust Details E-FT-1 and E-FT-2 and E-FT-3.
Performance Treated floor meets with the descriptive FFT1, typically within Robust Details E-FT-1 and E-FT-2 and E-FT-3.
|
|
SPECIFICATION:
The acoustic floor shall be: Ecocheck Deep Batten, by Custom Audio Designs Ltd, Unit 2, Amey Industrial Estate, Petersfield, Hampshire, GU32 3AN and installed in accordance with manufacturer's instructions / recommendations. | |
DOWNLOAD PDF
DOWNLOAD INSTALLATION DETAILS
|
![]() ![]() ![]()
|
| GENERAL DATA | ||||||
| Product | Minimum Void Height | Typical Application | ||||
| Part Code | Height | Width | Length | Timber (RSD) | Concrete (RSD) | |
| AB45 | 45mm | 45mm | 1800mm | 45mm | E-FC-1, E-FC-2, E-FC-7 | |
| AB54 | 54mm | 45mm | 1800mm | 45mm | E-FC-1, E-FC-2, E-FC-7 | |
| AB61 | 61mm | 45mm | 1800mm | 45mm | E-FC-1, E-FC-2, E-FC-7 | |
| AB70 | 70mm | 45mm | 1800mm | 70mm | E-FC-1, E-FC-2, E-FC-7 | |
| AB75 | 75mm | 45mm | 1800mm | 70mm | E-FT-1, E-FT-2, E-FT-3, E-FS-1, E-FS-2 | |
| All information contained in these details is given in good faith but without warranty.
Custom Audio Designs reserves the right to alter the specifications of any product without notice. | |
| ©Custom Audio Designs 2009 | |