Acoustic Rated Fire Hoods for Ceiling Downlighters
USES:
  • Meets BS EN 1365-2:2000 and BS476 Part 23:1987
  • Can be used in suspended, plasterboard or concrete ceilings
  • Covers a wide range of mains & low voltage downlighters
  • Lightweight & flexible cover can be fitted from below or above the ceiling
  • Provides a highly insulating stable char when exposed to fire
  • Prevents fire from penetrating the ceiling void and retains ceiling's fire protection integrity
BENEFITS:
  • Acoustic Rated
  • 30 or 60 minute fire rating
  • Installed in seconds
  • No screws, drilling or additional supported required
  • Maintenance free
  • Ventilated to reduce heat build up
  • Once fitted downlighter can be fitted as normal
Acoustic Rated Fire Hoods for Ceiling Downlighters

Acoustic Rated Fire Hoods for Ceiling Downlighters
  Ceiling downlighters are widely used in residential and commercial buildings. Each ceiling is subject to fire regulations and where applicable the ceiling construction needs to be fire rated.

However, once a hole has been made in the ceiling for a downlighter, the soundproofing performance of the construction is seriously reduced. In addition the ceilings ability to perform in a fire can be reduced significantly as well which can be very dangerous.

To combat this the Intumescent Acoustic Hood has been developed to give maximum acoustic and fire protection protection for holes created by he installation of downlighters and to allow for maximum ease of fitting.

In a fire situation the cover expands internally (swells to over 3 times its original thickness) to fill all the available space with a highly insulating fire resistant char. Thus, the fire is unable to penetrate the hole and the cover is able to give additional insulation protection to the ceiling void to reduce the chance of heat build up and ignition of flammable materials such as accumulated dust and insulation.

The cover also adds mass behind the ceiling light which improves the soundproofing performance. Acoustic tests show that a ceiling with downlighters and acoustic hoods installed performs to within 1dB of the equivalent ceiling without any holes in it at all!!

This product does not present any known health hazards during or after installation.

Local Authority Building Control LANTAC Approved
acoustic and fire hoods for ceiling downlighters acoustic and fire hoods for ceiling downlighters
acoustic and fire hoods for ceiling downlighters acoustic and fire hoods for ceiling downlighters

ACOUSTIC TEST DATA
Separating Floor with no LightsAirbourneRw 66 (-5;-12) dBImpactLnw 54 dB
Separating Floor with 9 halogen downlighters and Acoustic HoodsAirbourneRw 65 (-5;-12) dBImpactLnw 54 dB
Internal Floor with no LightsAirbourneRw 41 (-2;-7) dBImpactLnw 79 dB
Internal Floor with 9 halogen downlighters and Acoustic HoodsAirbourneRw 42 (-2;-7) dBImpactLnw 80 dB


acoustic and fire hoods for ceiling downlighters   SELECTION GUIDE
  • All covers are equally suitable for mains or low voltage fittings using "cool beam" dichroic or aluminium reflector lamps. It is only necessary to know the cut-out size and the height of the fitting.
  • Select the cut-out size of the fitting in the left hand column.
  • Read across to the right hand column that contains the height of the fitting concerned. Always select the exact height, or move up to the next size.


For example:
A cover for a fitting with a 98mm cut-out and a height of 95mm is required. In the left hand column you will see that the nearest cut-out size is 100mm; reading across the right hand columns, you will note that the SMALL is not suitable, the 83mm fitting height for the MEDIUM shown is also too small so you should select the LARGE size.

Please note: if your fitting size is shown in the orange shaded area the cover can only be fitted from above the ceiling as the cover will NOT fit through the cut-out hole.


Part CodeSizeO/D x height mm
FH100Small150 x 150
FH110Medium200 x 200
FH120Large250 x 250
FH130Extra Large370 x 210
FH140XL Extra Large450 x 255
fire hoodsDownload PDF
fire hoodsDownload INSTALLATION Details
Acoustiwrap E-coustiwrap soundproof pipewrap

All information contained in these details is given in good faith but without warranty.
Custom Audio Designs reserves the right to alter the specifications of any product without notice.
©Custom Audio Designs 2006

Valid HTML 4.01 Transitional