Part E Building Regulations
Part E Building Regulations
home products products products products
Part E Building Regulations

Soundproofing Solutions to Meet New Part E Building Regulations

Separating Timber Floors / Timber Joist Floor / 60 RwdB + Ctr  -  46 LnwdB Application

Part EDownload PDF Data Sheet
Sound Reduction Performance
AirborneImpact
RwdBRwdB+CtrLnwdB
706046
Acoustic Requirement: New Build
Airborne: 45 DnTw+CtrdB
Impact: 62 LnTwdB
Acoustic Requirement: Refurbishment
Airborne: 43 DnTw+CtrdB
Impact: 64 LnTwdB
Components and Fixing Data:
  • 1 x 18mm T&G Chipboard (laid on)
  • Resilient Tape (on)
  • 25 x 50mm Timber Battens (at 400mm centres on)
  • 3.5mm Neoprene Pads (on)
  • 52mm Acoustic Quilt (between battens)
  • 18mm Chipboard (screwed to)
  • Timber Joists (240 x 48mm at 400mm centres. Joist size to suit application)
  • 52mm Acoustic Quilt (beneath joists)

    Independant Ceiling:
  • Timber Joists (100 x 48mm on hangers at 400mm centres)
  • 1 x 15mm Plasterboard (screwed to independant joists)

  • Right Click the Graph to Enlarge
    Technical Data:
    Mass per Unit Area:
    Footprint Width:
    Fire Protection:

    76.2Kg/m²
    377mm
    30 minutes (2 layers plasterboard = 60 minutes)