Part E Building Regulations
Part E Building Regulations
home products products products products
Part E Building Regulations

Soundproofing Solutions to Meet New Part E Building Regulations

Separating Wall / 70mm Acoustic Stud / 51 RwdB +Ctr Application

Part EDownload PDF Data Sheet
Sound Reduction Performance
61 RwdB51 RwdB+Ctr
Part E Acoustic Requirement
New Build
45 DnTw+CtrdB
Refurbishment
43 DnTw+CtrdB
Components and Fixing Data:
  • 15mm Acoustic Plasterboard (and)
  • 12.5mm Plasterboard (screwed to)
  • Resilient Bars (at 600mm centres)
  • 70mm Acoustic Studs (at 600mm centres)
  • 52mm Acoustic Quilt (Between studs)
  • Resilient Bars (at 600mm centres)
  • 12.5mm Plasterboard (screwed to resilient bars)
  • 15mm Acoustic Plasterboard (screwed through to resilient bars)

  • Right Click the Graph to Enlarge
    Technical Data:
    Mass per Unit Area:
    Footprint Width:
    Fire Protection:

    51.8Kg/m²
    145mm
    60 minutes
    ©Custom Audio Designs 2004