Part E Building Regulations
Part E Building Regulations
home products products products products
Part E Building Regulations

Soundproofing Solutions to Meet New Part E Building Regulations

Separating Wall / Independant Metal C Metal Stud / 53 RwdB +Ctr Application

Sound Reduction Performance
66 RwdB53 RwdB+Ctr
Part E Acoustic Requirement
New Build
45 DnTw+CtrdB
Refurbishment
43 DnTw+CtrdB
Components and Fixing Data:
  • 1 x 12.5mm Plasterboard (screwed to)
  • 48mm Metal C Studs (at 600mm centres)
  • 52mm Acoustic Quilt (Between studs)
  • 20mm Clear Cavity
  • 100mm Lightweight Block Wall (painted one side)
  • 20mm Clear Cavity
  • 48mm Metal C Stud (at 600mm centres)
  • 52mm Acoustic Quilt (between studs)
  • 1 x 12.5mm Plasterboard (screwed to studs)

  • Right Click the Graph to Enlarge
    Technical Data:
    Mass per Unit Area:
    Footprint Width:
    Fire Protection:

    90.1Kg/m²
    261mm
    N/A
    ©Custom Audio Designs 2004